© 20 17 , Slide Sledge, LLC 27 6. Slide Sledge ™ Multi-Head ™ Hammer Disassembly 1.To remove the plunger, plunger housing and spring, heat the plunger housing to 450 degrees Fahrenheit with flameless heat to break down the Loctite ® 243 Threadlocker or CAT ® Thread Lock Breakaway Strength 9S- 3263. Unscrew the plunger housing in a counterclockwise direction to remove. NOTE: Always wear heat resistant gloves when working with metal parts that have been heated. How to remove and replace the Plunger, Plunger Housing and Spring 2.After removing the plunger housing, sepa- rate the plunger and plunger spring from the plunger housing. You can now replace any of the components. Reverse the procedure to install. 3.Before re-assembly, place a full circle of Loctite ® 243 Threadlocker or CAT ® Thread Lock Breakaway Strength 9S-3263 around the threaded area of the outer tube, then screw the plunger housing onto the threads on the drive bar tube in a clockwise direction. Be sure to thread plunger housing forcefully until the plunger housing can be threaded no further.